A certificate of analysis (COA) is a batch-specific record of tests and results. Here is what to check on one for MOTS-c, and what identity and purity results can—and cannot—tell you.

Short answerLab literacy · 6 min read · Updated 21 Nov 2026

A MOTS-c certificate of analysis (COA) should identify the material and batch, state which tests were run, and report the method, acceptance limit, result, date, and responsible laboratory or reviewer. For MOTS-c, an identity result and a chromatographic purity percentage answer different questions. Neither alone proves the vial matches the report.

Key takeaways

  • Match the compound name and batch number on the report to the vial label.
  • An identity result concerns what the method detected; a purity percentage is specific to its test method.
  • A purity percentage does not, on its own, state the amount of MOTS-c in the vial.
  • Look for the test method, acceptance limit, result, date, and laboratory or authorized reviewer.

01What to check on a MOTS-c COA, field by field

Use this checklist to read the report beside the vial. A field that is missing is a question to resolve, not a result to assume.

FieldWhat to checkWhy it matters
1. Material identityThe named material and, where supplied, its sequence or chemical form.Check that the report describes MOTS-c, not just “peptide” or a generic sample.
2. Batch or lotA batch identifier that can be compared with the vial label.A report for a different batch does not document the vial’s batch.
3. Sample referenceA sample identifier or other clear link between the tested sample and the batch.It helps show which submitted sample the results describe.
4. Laboratory and responsible reviewerThe laboratory’s name and contact details, plus an authorized signature or reviewer identification.These details identify who performed or released the analysis.
5. Test and methodEach test, with its method named clearly enough to distinguish identity, purity, or content testing.Different methods answer different analytical questions.
6. Acceptance limitThe specification or limit for each reported test.A result without its stated criterion is harder to interpret.
7. Numerical resultThe measured value for each numerical test, with units where relevant.“Pass” alone gives less information than a result beside its limit.
8. Dates and release statusTest or release date and, if assigned, a retest or expiry date; check the report’s release or disposition statement.These details place the record in time and show the stated batch disposition.

FDA’s Q7A guidance describes COA information including the material name, batch number, release date, tests, acceptance limits, numerical results where applicable, and authorized sign-off. Where a repacker, reprocessor, agent or broker issues a new certificate, it says the certificate should show the laboratory that performed the analysis. This is a reading checklist, not a claim that every research-material report follows a regulated drug-manufacturing standard.

02What an identity result means for MOTS-c

FDA staff’s 2026 briefing describes MOTS-c as a peptide of 16 amino acids, MRWQEMGYIFYPRKLR in one-letter code. On a report, an identity result is meaningful only in relation to the method used and the material the method is meant to identify. Mass spectrometry can measure molecular mass; other methods may add supporting identity information. A report that only says “identity: pass” does not show you the underlying comparison.

1
Read the named analyte

Check that the report names MOTS-c and does not leave the sample as an unnamed peptide.

2
Find the method and result

Look for the method used and a reported result or reference comparison. A method name alone is not a test result.

3
Check the batch link

Compare the report’s batch identifier with the one on the vial. A correct identity result for another batch does not establish the identity of this batch.

Sequence or form details matter when the report gives them. A named sequence helps distinguish the intended material from a report that identifies only a broad category. It does not, by itself, verify the tested sample or connect that sample to a particular vial.

03What the purity percentage means

Identity

Which material?

An identity method asks whether the test supports the named material. Check the method and the reported result.

Purity

What did the method separate?

A chromatographic purity result describes a separation-based measurement. Its meaning depends on the method and the signal included in the calculation.

Content

How much material?

A content or assay measurement is a separate question. Do not read a purity percentage as the amount of MOTS-c in the vial.

For example, “99% purity” is incomplete without the method and its scope. A chromatographic percentage is a result from that chromatographic procedure; it is not automatically a measurement of net peptide content or a mass amount in the vial. HHS’s peptide testing table lists assay and net peptide content as separate quality attributes, with different analytical procedures.

Purity also has limits as a summary. A single percentage does not name every impurity, show what the method could detect, or establish a separate test’s result. Read the method, acceptance limit, and actual result together. If a report presents only a percentage, ask what test produced it and what that percentage represents.

For more on the separation method, see how HPLC is described in a report. For mass-based identity methods, see mass spectrometry explained.

04Match the COA to the vial

Start with the identifiers, then read the results. Do not use one field as a substitute for another.

1
Compare the names

Check the vial label and report for the same named material. Note any sequence, salt, or form details stated on either record.

2
Compare the batch identifiers

Look for the same lot or batch number. If the label and report differ, the report does not establish a match to that vial.

3
Read each test line

For each result, find the method, acceptance limit, and measured value. Keep identity, purity, and content as separate questions.

4
Check who issued the record

Find the laboratory details and authorized reviewer or signature. If another party issued the report, check whether it identifies the laboratory that performed the analysis.

A COA describes the sample and tests recorded in that report. It does not by itself establish that an untested vial has the same contents. It also cannot replace a test that the report does not list. For general report-reading guidance, see how to read a COA.

05What a COA cannot tell you

A COA is not a universal quality verdict. It records specified tests and results for a stated sample or batch. The report does not answer analytical questions it did not test.

  • A purity result alone does not confirm identity or state the amount of MOTS-c in the vial.
  • An identity result does not establish a purity or content result unless those tests are separately reported.
  • A report for one batch does not document a different batch.
  • A “pass” statement without the test, method, limit, and result leaves key context out of view.

We do not know what a particular vial contains from a general explanation of COAs. You need the report for the matching batch and the details of the tests it actually records.

RefSources

  1. U.S. Food and Drug Administration. IND chemistry, manufacturing, and controls information. Guidance page, accessed 21 Nov 2026. www.fda.gov/drugs/investigational-new-drug-application-ind/i…
  2. U.S. Food and Drug Administration. Q7A Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients. Guidance, sections 7.3 and 11.4. www.fda.gov/regulatory-information/search-fda-guidance-docum…
  3. U.S. Food and Drug Administration. Biotechnology Inspection Guide. Inspection guide, HPLC and mass spectrometry entries. www.fda.gov/inspections-compliance-enforcement-and-criminal-…
  4. European Medicines Agency. ICH Q2(R2) Validation of Analytical Procedures. Scientific guideline, current version. www.ema.europa.eu/en/scientific-guidelines/ich-q2r2-validati…
  5. U.S. Department of Health and Human Services. Enforcement discretion policy regarding 503A compounding using certain peptide bulk drug substances (draft), Appendix B: analytical testing table (“Assay (Drug Substance)”; “Peptide Content (Net)”). Read on the Internet Archive capture of 15 Nov 2026, the newest readable one (hhs.gov returned 403 to our tools). web.archive.org/web/20261115103435/https://www.hhs.gov/sites…
  6. U.S. Food and Drug Administration. FDA briefing document, Pharmacy Compounding Advisory Committee meeting of 23–24 July 2026: MOTS-c-related bulk drug substances. Advisory committee briefing, 2026 (p. 9); read 21 Nov 2026. www.fda.gov/media/193347/download

Plain-English summary of public sources, not legal or medical advice. Last checked 21 Nov 2026.

Questions

Does a high MOTS-c purity percentage prove the vial contains that amount?

No. A purity percentage is a method-specific result, not automatically a measurement of net peptide content or mass in the vial. Look for a separate content or assay result and its method.

What should the identity result on a MOTS-c COA show?

Check that the material is named, that the identity method is stated, and that a result or reference comparison is reported. The report’s batch identifier should also match the vial.

Is “pass” enough to interpret a COA?

Not on its own. Check which test passed, the method used, its acceptance limit, the result, and whether the report identifies the matching batch.

Does a COA for one batch cover every vial?

A batch-specific report documents the sample or batch stated on that report. Compare its batch identifier with the vial; do not assume a report for another batch applies.