Key takeaways
- Twelve rows, scored 0, 1 or 2 from evidence you can see, for a maximum of 24.
- Read the zeros first: a 0 on lab, report per lot, purity method or identity method outweighs any total.
- Rows 11 and 12 test honesty: human-use claims and undisclosed paid posts are red flags, not features.
- A score describes paperwork and conduct for one lot; it says nothing about safety or effect in people.
- We invite readers to audit 6AM with the same template.
01How to use the template
Pick one supplier. Collect what it shows you. Score each row from the evidence in front of you, not from what you are told.
The lab report for one lot, a photo of the vial label, the product listing, the supplier's contact page and one paid post by an affiliate or creator.
Use the descriptions in the last column. If you cannot see the evidence, the score is 0.
A 0 on rows 1 to 4 means the paperwork cannot support the vial, whatever the total. Then add up the rest; the maximum is 24.
A score describes one lot and one moment. Rows 2, 3, 4 and 5 can change with every new batch.
02The scorecard
| Check | What good looks like | Red flag | Score (0/1/2) |
|---|---|---|---|
| 1. Lab named | The report names an independent testing lab, with its address, and that lab will confirm it issued the report. | No lab named, a logo with no name, or the seller's own name in the lab field. | 0 none · 1 named · 2 named and the lab confirms the report |
| 2. Report per lot | A separate report for every lot, matched by lot number. | One report used for every lot, or the same report image on several products. | 0 no report · 1 one report per product · 2 one report per lot |
| 3. Purity method | Purity by HPLC, with the percentage and the chromatogram trace. | A round figure such as "99%+" with no method and no trace. | 0 no purity result · 1 figure with method · 2 method and trace |
| 4. Identity method | Identity by mass spectrometry, with the observed mass next to the expected mass. | Purity only, or "identity confirmed" with no data behind it. | 0 none · 1 stated without data · 2 mass spectrometry with both masses |
| 5. Endotoxin tested | An endotoxin result with its units (EU/mg) and method (LAL or recombinant factor C). | Not mentioned at all, or "pass" with no number and no method. | 0 none · 1 pass/fail only · 2 value, units and method |
| 6. Lot on label | The lot number printed on the vial label itself, matching the report. | No lot number on the vial, or a sticker covering the original label. | 0 none · 1 on the outer box only · 2 on the vial, matching |
| 7. Live result page | A page or QR code for each lot where the report can be opened and checked against the lot number. | Reports only as screenshots, sent in private messages "on request". | 0 none · 1 on request · 2 a page per lot you can open yourself |
| 8. Scientist reachable | A named person with a science background who answers questions about methods and reports. | Only a sales chat, and method questions go unanswered. | 0 no reply · 1 general support replies · 2 a scientist answers |
| 9. Cold chain | Stated conditions for transit and storage, and packaging that matches what is stated. | No information at all about temperature in transit or in storage. | 0 nothing stated · 1 storage advice only · 2 transit and storage stated and matched |
| 10. Discreet packaging | A plain outer box, and inside a full label: compound, contents in mg, lot and the research-use line. | Contents disguised or declared as something they are not. | 0 disguised · 1 plain but label incomplete · 2 plain outside, full label inside |
| 11. Claims on the site | Products described by what they are (sequence, identity, purity), with research-use terms, and education kept apart from listings. | Amounts, schedules, how-to-use guides, before-and-after pictures or outcome stories next to products. | 0 human-use claims · 1 research framing with lapses · 2 what it is, never what it does to people |
| 12. Disclosure practice | Creators and affiliates label paid posts clearly, up front, and the seller says publicly that it pays them. | Affiliate codes posted with no label, or paid reviews that are not marked. | 0 none · 1 inconsistent · 2 every paid post labelled |
For research materials only. This template audits paperwork, labelling and conduct. It says nothing about use in people.
03Why these twelve rows
Rows 1 to 7 test the paperwork. They exist because a purity number alone answers very little. In its briefing for the July 2026 Pharmacy Compounding Advisory Committee, the FDA reported that most certificates of analysis it found for BPC-157 showed a purity result only, with no impurity limits. The same briefing noted that the certificate a nominator supplied for BPC-157 acetate mentioned no endotoxin test. Read more in endotoxin and sterility testing.
Row 6 borrows a rule from medicines. US regulations say the lot number on a drug label should lead back to the complete manufacturing history (21 CFR 201.18). Research vials are outside that rule; the logic still holds.
Rows 8 to 10 test the people and the handling. A supplier that cannot answer a method question cannot defend its own report. Packaging should protect the contents and your privacy, never hide what the contents are.
Rows 11 and 12 test honesty. In warning letters dated 24 August 2026, the FDA told five research-use peptide websites that their research-use labels did not settle the matter, citing product-page wording and the sale of bacteriostatic water alongside vials as evidence that the products were meant for people. On disclosure, the US Federal Trade Commission requires a material connection between an endorser and a seller to be disclosed clearly and conspicuously when the audience would not reasonably expect it (16 CFR 255.5). In the UK, the influencer guide from the ASA, CAP and the CMA says it must be obvious that an ad is an ad, and recommends a clear label such as #ad up front.
04What a score can't tell you
- A score cannot confirm what is in a vial. Only a test of that vial, or of a retained sample from the same lot, can.
- A perfect score can rest on a forged report. Row 1 asks you to confirm the report with the lab for that reason.
- A high score says nothing about whether a compound is safe or effective in people. Those are evidence questions; see how we grade evidence.
- We have not set a pass mark. Two suppliers on the same total can fail in very different places, which is why the zeros come first.
05Audit us too
We would like you to run this audit on 6AM. 6AM publishes a lab report for every batch on our quality page. Score us from what you can see, the same way you would score anyone else.
We have not scored ourselves here. Marking our own work would prove nothing. [When the testing lab and report scope are confirmed, publish 6AM's evidence for each row so readers can check it.]
If you audit us and find a gap, tell us through the contact page. For single vials rather than suppliers, use the 10-point safety checklist.
Educational content. Not medical advice. This is a plain-English summary of public sources as of 17 November 2026, not legal advice.